Oki RT322POS Uživatelský manuál Strana 48

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 60
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 47
– 44 –
No. 1 2 3 4 5 6 7 8 No. 1 2 3 4
9 10
DIP-SW 1 DIP-SW 2
10-4. EthernetInterface Model
ON ON
OFF OFF
DIP-SW 1
Switch 1-1 Switch 1-2 Command emulation
ON ON Star Line Mode
OFF ON Star Page Mode
ON OFF -
OFF OFF ESC/POS Mode
The factory settings of DIP switch are all on.
The functions of switches 1-3 through 1-10 will change according to the command emulation
that has been set using switch 1-1 and 1-2.
(1) Star Line Mode
Switch Function ON OFF
1-1 Command emulation Always ON
1-2 Command emulation Always ON
1-3 Should not be changed (Should be set to on)
1-4 Sensor adjustment Invalid Valid
1-5 Should not be changed (Should be set to on)
1-6 Handshaking conditions
(conditions for BUSY)
Ofine or receive
buffer full
Receive buffer full
1-7 ASB function *1 Valid Invalid
1-8 NSB function *2 Valid Invalid
1-9 ~1-10 Should not be changed (Should be set to on)
2) Star Page Mode
Switch Function ON OFF
1-1 Command emulation Always OFF
1-2 Command emulation Always ON
1-3 Should not be changed (Should be set to on)
1-4 Sensor adjustment Invalid Valid
1-5 Should not be changed (Should be set to on)
1-6 Handshaking conditions
(conditions for BUSY)
Ofine or receive
buffer full
Receive buffer full
1-7 ASB function *1 Valid Invalid
1-8 NSB function *2 Valid Invalid
1-9 ~1-10 Should not be changed (Should be set to on)