F
USER
REPLACEMENT
The fuser is located inside the printer just behind the toner cartridges.
Switch off the MFP and allow the fuser to cool for about 10 minutes before opening the
cover. Refer to “Turning off your machine” on page 19 for details.
1. Gently raise the scanner.
2. Press the cover release (a) and open the output tray (b) fully.
3. Identify the fuser handle (a) on the top of the fuser unit.
4. Pull the two fuser retaining levers (b) towards the front of the printer so that they
are fully upright.
5. Holding the fuser by its handle (a), lift the fuser straight up and out of the printer. If
the fuser is still warm, place it on a flat surface which will not be damaged by heat.
6. Remove the new fuser from its packaging and remove the transit material.
WARNING!
If the MFP has recently been powered on, some fuser components
will be very hot. Handle the fuser with extreme care, holding it only
by its handle, which will only be mildly warm to the touch. A
warning label clearly indicates the area.
a
b
b
b
a